5600 Series Wired Flush-mounting Discussion System with Interpretation( Discussion Module+ Interpretation Module)

System Overview

GONSIN 5600 digital conference system is designed to provide a versatile flush mounting solution including five function modules such as basic discussion module, simultaneous interpretation module, voting module, extended handheld voting keypad module, loudspeaker module. All these modules are self-contained and can be flexibly configured, enabling conference terminals to offer more or less functions. Discussion unit allows the delegate to talk and request to talk, with automatic video tracking and a RJ-45 expansion port for additional plug-and-play handheld voting keypad. Channel selection unit offers 6 channels for participants to hear the selected channel through a personal headphone and adjust the volume level for comfortable listening. Voting unit is used for attendance registration, voting, election and evaluation. Loudspeaker can be added to the discussion unit depending on the venue needs.

 

System Features

Flexible module-based solution

Five function modules can be stand-alone installed or easily combined to meet the exact customer needs, offering a versatile conference solution.


Smart voice activation mode

The system can be operated under VOX mode so that the microphone is automatically turned on when the delegate speaks. VOX sensitivity can be set to H/M/L to suit conference environment. Voice activation mode enables hands-free operation with no need to push the microphone button.


Future-proof system expansion

TL-5600 system offers perfect solution to upgrade the system and extend more features when necessary. Expansion port is designed to easily connect plug-and-play handheld module.

 

Proudct Features

◆ Elegant and fashion design

◆ Exquisite manufacturing process

◆ Flexible module-based solution

◆ Expansion interface for system upgrading

◆ LED indicator for working status

◆ Channel, volume and VOX sentitivity displayed on LCD screen

◆ Volume of loudspeakers can be set alone or together

◆ Multiple chairman or vice chairman units are allowed

◆ Support auto camera tracking function ( SD and HD)

◆ Electret cardioid pickup pattern microphone, rich timbre

◆ Pluggable microphone stem with red indicator light ring

◆ Highly resistant to mobile phone interference



Projects

*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~




Iraq Medical Center
Olsztyn University, Poland
Plenary Hall, City ALICANTE



Discussion Unit TL-VDQ5600/ TL-VXQ5600

Delegate discussion unit (TL-VDQ5600) allows the delegate to talk, request to talk, and register attendance. 1 to 4 delegate microphones can be active simultaneously. Built-in loudspeaker automatically mutes when the microphone is turned on. Chairman discussion unit (TL-VXQ5600) has the additional priority button to override all active delegate units to control the conference. Multiple chairman and vice-chairman discussion units can be used in one system, and can be active at any time regardless of preset delegate microphone limit.


Main Features

◆ Voice-activated microphone mode
◆ Low susceptibility to interference from mobile phones
◆ Pluggable gooseneck microphone stem
◆ Waterproof and dustproof design
◆ Long microphone pick-up range
◆ Red ring luminant to identify active unit
◆ Blue LED indicator for chairman or VIP


Basic Functions

◆ Microphone mode: VOX/AUTO/FIFO/OPERATOR/Request to speak( with software)
◆ Unlimited number of chairman units or vice chairman units
◆ System supports hot-plugging
◆ Six kinds of detachable microphone stem for various conferences
◆ Support control speak time with software
◆ Anti-nonself design for extended interfaces, make it more durable
◆ Basic discussion unit comes with RJ45 extended interface for plug-and-play voting keypad to realize voting, election, evaluation functions
◆ Attendance: registration by keypress or late registration
◆ In VOX mode, microphones will be activated as users speak. VOX sensitivity (high/middle/low) and mic time-out(20-250 seconds) can be adjusted by the server. Besides the chairman unit, 4 delegate unit can be activated at the same time.
◆ Blue indicators of Chairman and vice chairman unit are always on.
◆ Automatic video tracking, with preset position for panorama view


Besides the function of delegate unit, chairman unit has following functions:
◆ Chairman unit can be activated at any time
◆ Chairman unit can override/mute all the active delegate units

 

Technical Specifications

Installation

flush mounting

Frequency response

30Hz~20KHz

Max SPL

125dB (THD<3%)

Dynamic range

85dB

Sensitivity

-46dB±4dB

THD

THD<0.3%

SNR

≥95dB

Power

24V

VOX Sensitivity

High/Middle/Low 77dB/80dB/82dB three modes

VOX auto mic time-out

6~180 seconds

Microphone stem length

410mm(standard) 310mm/510mm optional

Dimension (L×W×H)

100mm×40mm×60mm

Hole Dimension (L×W)

124±4×33±2 table thickness ≥15mm

Weight

0.08Kg

Working temperature

0~45

Storage temperature

-20~50

 

Functions Indicators

1. RJ-45 internet connector to connect the hand-held voting unit
2.Microphone stem socket , connect to pluggable microphone stem .
3.Blue LED light , when the discussion unit is chairman unit or vice-chairman unit , LED light turns on .
4. is the chairman PRIO button
5. is registration / microphone on off/ number writing button



Projects

*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*




University of Science and

 Technology of China


Hall of operational meetings of 

the Academic Council


Ural Institute of state 

fire fighting service,Russia



Channel Selection Unit TC-Q5600

The wired flushmount channel selection unit provides high immunity from interference and high security against unauthorized listening. Each unit comes with headphone jack and volume control so that the delegate can hear any selected channel on a personal headphone, and adjust volume level for comfortable listening.


Main Features

◆ Simple and stylish look
◆ 30000V ESD protection circuit design
◆ Waterproof and dustproof design


Basic Functions

◆ 6 selectable channels for interpretation
◆ Interpretation volume level can be adjusted individually, or centrally by CCU
◆ Selected channel number, volume and VOX sensitivity are shown on LCD
◆ Rich timbre


Technical Specifications

Mounting type

flush mounting

THD

<0.3%

SNR

≥95dB

Channel number

6 channels

Powered

by the central control unit

LCD

Dimensions: 17mm×14mm

Earphone jack

3.5mm jack stereo

Dimension (W×D×H)

100mm×40mm×60mm

Hole Dimension(L×W)

124±4×33±2table thickness≥15mm

Weight

0.06Kg

Working temperature

0~45

Storage temperature

-20~50


Functions Indicators


1.Eearphone jack ( ), 3.5mm jack for earphone listening
2.Headphone listening volume control button
3.Interpreting module LCD displayer ,it display Channel ,volume and VOX sensistivity
a. Seting the delegate headphone listening volume ,theLCD displayer display the volume 0-31
b. Setting the sound control sensibility via the central control unit , it also display in the LCD displayer ( 10 is the lowest ,16 is middle ,25 is the highest )
c. Setting the interpreting channel ,the LCD dispayer display channel number 0-5
4. Channel selection button ,5600 interpreting system support 6 channels (include floor language) voice singnal transmission, press ▲▼ button to choose 0-5 channel ,total 6 channels .


Projects

*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*




University of Science and

 Technology of China


Hall of operational meetings of 

the Academic Council


Ural Institute of state 

fire fighting service,Russia


 



Loudspeaker SPK-10

The flush loudspeaker delivers natural and clear sound. When it is used with the flush discussion unit, any smaller conference can be held without external sound equipment.


Main Features

◆ Simple and stylish design
◆ High-definition audio processing
◆ 30000V ESD protection circuit MIC is turned on


Basic Functions

◆ Loudspeaker volume level can be adjusted individually, or centrally by CCU
◆ Human-friendly inclination angle, make its performance better


Technical Specifications

Mounting type

flush mounting

Powered

2W/8Ω

Frequency response

200Hz~16KHz

Sensitivity

89dB

Powered

by the central control unit

Dimension(W×D×H)

100mm×40mm×70mm

Hole Dimension(L×W)

124±4×33±2(table thickness15mm)

Weight

0.09Kg

Working temperature

0~45

Storage temperature

-20~50



Projects

*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*




University of Science and

 Technology of China


Hall of operational meetings of 

the Academic Council


Ural Institute of state 

fire fighting service,Russia



Central Control Unit TC-ZB4

Main Functions

Extended functions under PC and software control
•Voting: Yes, No, Abstain . Vote counting and result display are enabled automatically by PC
               Single-choice and multiple-choice voting
               First key-press and final key-press voting
•Election: elect one or more out of N candidates, with 'competitive election', 'equal number election' and ’quick election’
•4-key evaluation: Good, Fair, Poor, Abstain.
•Utilize multi-level error correction and data encryption technique to ensure information security.
•Customized voting options and voting methods, support customized language mode or display screen
•Language interpretation: 1+5 channels.
•Acoustic frequency response can up to 20Hz~20KHz.
•With interpreter unit and language distribution port, it can connect Gonsin IR simul-taneous
•interpretation system or FS-FHSS wireless simultaneous interpretation system for compatible use.


Technical Parameters

Max System Capacity4096
Standard Capacity60~70(different from various models)
Acoustic Frequency Response20Hz~20KHz
SNR>96dBA
Channel Isolation>85dB
Dynamic Range>94dB
THD<0.05%
PowerAC100~240V,50/60Hz
Audio Port1 balanced (XLR)
2 unbalanced (RCA)
Max Audio OutputLINE OUT :+20 dBu unbalanced
BLANCE OUT :+20 dBu balanced
Output Impedance>1KΩ
External Audio Input0.775V (PHOENIX terminal)
Central Control MethodRS-232
PC Connection MethodTCP/IP
Camera Control MethodRS-485
Max Power Consumption300W
Terminal Connection Port8-pin×4
13-pin×4 (for TC-Z4,TC-ZB4 only)
Channel selection6 (for TC-Z4,TC-ZB4 only)
Display ScreenOLED (61mm×37mm)
Audio recording portUSB (USB:FAT32)
Audio recording File Size0.8M/m
Active Delegate1/2/3/4 (not including chairman unit)
VOX sensitivityH/M/L (76dB/80dB/82dB)
Support Camera Number4 SD cameras (built-in SD matrix), MAX 8 cameras with extended matrix
Video Input PortRCA×4 (1Vp-p 75Ω)
Video Output PortRCA×2 (1Vp-p 75Ω)
Camera Tracking ProtocolPELCO-P/PELCO-D/VISCA
Operating Temperature-0~45℃
Storage Temperature-20~50℃
Dimensions (L*W*H)485mm×350mm×90mm
InstallationDesktop or 19" rack mounting
Weight7.6Kg




Projects

*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*




University of Science and

 Technology of China


Hall of operational meetings of 

the Academic Council


Ural Institute of state 

fire fighting service,Russia



Connector CON-5600

The CON-5600 connector is designed to connect control units to function modules including discussion unit, channel selection unit, flush voting unit and/or loudspeaker for power supply and communication signals.


Technical Specifications

Working temperature

0~45

Storage temperature

-20 ~ 50

Dimensions (WxDxH)

167x160x40mm

Net weight

1083 g



Projects

*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*




University of Science and

 Technology of China


Hall of operational meetings of 

the Academic Council


Ural Institute of state 

fire fighting service,Russia




Extension Unit ZJ-KR

Functions

•Confirm to IEC 60914 international standard.
•With full digital audio technology, built-in high-speed CPU and high-performance DSP digital audio processor.
•Black tempered glass panel design, simple and high-end design. All the function divisions are clearly layout and easy to operate.
•Three routes 8-pin ports to connect conferenc units, another two route 8-pin port for system cascading.
•Three routes 13-pin ports to connect conferenc units, another two route 13-pin port for system cascading.
•Automatic restoration function: support hot plug and play.
•One central control unit is able to accommodate 60-70 units. By cascading extension units, the system can support upto 4096 conference units.
•Universal voltage power switch for wider usable range and sufficient power supply.

Technical Specifications

Max System Capacity4096
Standard Capacity60~70(different from various models)
PowerAC100~240V,50/60Hz
MAX Power300W
Terminal Connection Port8-pin ×5,13-pin×5
Operating Temperature0~45°C
Storage Temperature-20~50°C
Dimensions (L*W*H)485mm×350mm×90mm
InstallationDesktop or 19" rack mounting
Weight7.6Kg



Projects

*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*




University of Science and

 Technology of China


Hall of operational meetings of 

the Academic Council


Ural Institute of state 

fire fighting service,Russia