5600 Series Wired Flush-mounting Voting System

System Overview

BJ-Q5600 voting system offers a wired flushmount conference solution for attendance, voting, election, evaluation and grading.


Main features:

◆ Unique computing techniques to ensure flawless accuracy

◆ Multi-level correction and encryption to offer data security

◆ Highly scalable system to support more than 10000 voters

◆ Daisy-chain terminal interconnection for easy cabling

 

Major system component parts:

central control unit, extension unit, flush voting unit, connector(conjuntion box), conference management software, computer and display equipment


Projects

*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~




Iraq Medical Center
Olsztyn University, Poland
Plenary Hall, City ALICANTE


Flush Voting Unit BJ-Q5600

The flush voting unit allows the delegate to register attendance and cast a vote for YES/ABST/NO, evaluation and election. Votes are counted automatically and the result is shown on display equipment such as large screen, projector/screen and white board. Results can be printed out or saved in CD.


Main Features

◆ Simple and stylish design
◆ LED indicator to show working status for attendance and voting
◆ Voting and evaluation options are defined by system software
◆ 30000V ESD protection circuit design

◆ Waterproof and dustproof design


Basic Functions

◆ Utilize unique auto tracking validation and comprehensive calculation technology
◆ Multiple correction and encryption for data process,ensure the data security
◆ Maximum system capacity is 4096 units
◆ Attendance registration: by IC card, key press. Two-color LED indicator to indicate the registration method and status
◆ Voting: Yes/No /Abstain . Vote count and result display are enabled automatically by PC
-- Normal voting and direct voting
-- Single-choice and multiple-choice voting
-- First keypress and final keypress voting
◆ Election: elect one or more out of multiple candidates, with 'competitive election', 'equal number election' and 'quick election’
◆ Evaluation (opinion polls): Best, Good, Fair, Poor. Evaluation method can be defined by the system software
◆ LED indicator will indicate working status of voting, election and evaulation


Technical Specifications

Mounting type

flush mounting

Powered

by the central control unit

Weight

0.08Kg

Dimensions

100×40×66mm (W×D×H)

Hole Dimensions

124±4×33±2(L×W)table thickness≥15mm

Working temperature

0 to 45

Storage temperature

-20 to 50



Projects

*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*




University of Science and

 Technology of China


Hall of operational meetings of 

the Academic Council


Ural Institute of state 

fire fighting service,Russia



Basic functions BJ-Z4


•In compliance with IEC60914 international standard
•With full digital audio technology, built-in high-speed CPU and high-performance DSP digital audio processor.
•Black tempered glass panel design, simple and high-end design. All the function divisions are clearly layout and easy to operate. 4 route port to connect conference units, the
•system has auto-repair function, sup-port hot plug-and-play.
•One central control unit is able to accommodate 60-70 units. By cascading extension units, the system can support upto 4096 conference units.
•Universal voltage power switch for wider usable range and sufficient power supply..
•Built-in auto-detection fo conference units; before conferences, self-test can be run for each conference units
•TCP/IP PC communication between central control unit and PC, which can achieve control management, remote fault diagnosis and remote update.

Extended functions under PC and software control
•ID number writing: the conference system
•supports automatically or manually assign ID to the corresponding equipment.
•Chairman unit can be defined freely, and be able to control the voting process and agenda control.
•Register function and real-time participants statistics
•Voting: Yes, No, Abstain . Vote counting and result display are enabled automatically by PC
Single-choice and multiple-choice voting
First key-press and final key-press voting
•Election: elect one or more out of N candidates, with 'competitive election', 'equal number election' and 'quick election’4-key evaluation: Good, Fair, Poor, Abstain..
•Utilize multi-level error correction and data encryption technique to ensure informa- tion security.
•Support management software dual-system hot backup function; One control computer can be set as backup and connect to the system; if the current computer has faults, the backup computer can be automatically hosted to ensure the smooth and continuous meeting.
•Customized voting options and voting methods, support customized language mode or display screen.
•Conference management software can becustomized.

Technical Specifications

Max System Capacity4096
Standard Capacity60~70(different fromvarious models)
PowerAC100~240V, 50/60Hz
Central Control MethodRS-232
PC Connection MethodTCP/IP
MAX Power300W
Max. cable length300m
Terminal Connection Port8-pin×4
Operating Temperature0~45°C
Storage Temperature-20~50°C
Dimensions (L*W*H)485mm×350mm×90mm
InstallationDesktop or 19" rack mounting
Weight7.6Kg


Projects

*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*




University of Science and

 Technology of China


Hall of operational meetings of 

the Academic Council


Ural Institute of state 

fire fighting service,Russia



Connector CON-5600

The CON-5600 connector is designed to connect control units to function modules including discussion unit, channel selection unit, flush voting unit and/or loudspeaker for power supply and communication signals.


Technical Specifications

Working temperature

0~45

Storage temperature

-20 ~ 50

Dimensions (WxDxH)

167x160x40mm

Net weight

1083 g


Projects

*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*




University of Science and

 Technology of China


Hall of operational meetings of 

the Academic Council


Ural Institute of state 

fire fighting service,Russia





Extension Unit ZJ-KR

Functions

•Confirm to IEC 60914 international standard.
•With full digital audio technology, built-in high-speed CPU and high-performance DSP digital audio processor.
•Black tempered glass panel design, simple and high-end design. All the function divisions are clearly layout and easy to operate.
•Three routes 8-pin ports to connect conferenc units, another two route 8-pin port for system cascading.
•Three routes 13-pin ports to connect conferenc units, another two route 13-pin port for system cascading.
•Automatic restoration function: support hot plug and play.
•One central control unit is able to accommodate 60-70 units. By cascading extension units, the system can support upto 4096 conference units.
•Universal voltage power switch for wider usable range and sufficient power supply.

Technical Specifications

Max System Capacity4096
Standard Capacity60~70(different from various models)
PowerAC100~240V,50/60Hz
MAX Power300W
Terminal Connection Port8-pin ×5,13-pin×5
Operating Temperature0~45°C
Storage Temperature-20~50°C
Dimensions (L*W*H)485mm×350mm×90mm
InstallationDesktop or 19" rack mounting
Weight7.6Kg


Projects

*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*




University of Science and

 Technology of China


Hall of operational meetings of 

the Academic Council


Ural Institute of state 

fire fighting service,Russia



System Components

DESCRIPTION

MODEL

QTY/PCS

Remark

AWired interpretation system

Central Control Unit

TC-ZB3

1

 

Channel Selection Unit, with volume control

TC-Q5600

   N

 

   Connector (conjunction box)

GON-5600

   N

 

Extension Unit

ZJ-KR

N

Optional

Interpreter Console with gooseneck microphone

TC-F06

N

 

Interpreter Headset with  boom mic & volume control

TC-D2

N

 

Stereo Headphone, with super heavy bass

TC-D3

N

Optional

Single Earphone

TC-D1

N

Optional